jandy jxi check ign steps error

By Restricted Air Flow 7. Varying pump pressure can cause your Jandy JXi pool heater not to ignite. IPvFletch The possible causes include- fluctuating filter pump pressure, faulty flame sensor, bad pressure sensor, damaged fan/switch tubing, fan not operating or running slowly, restricted airflow, low gas supply pressure, malfunctioning gas valve, and air in the gas line. my Jandy JXI 400 heater is giving me a fault check . cleaned out gas jets. JavaScript is disabled. So, without a working igniter, you cant get your Jandy pool heater to light up. I had this error code recently and it turned out to be a broken ignitor. The heater has been giving me a bunch of trouble lately and I was hoping someone here may have some insight. Twice, though, I noticed it would shut off overnight and give me an ignition control fault message. Save my name, email, and website in this browser for the next time I comment. The heater has been giving me a bunch of trouble lately and I was hoping someone here may have some insight. I'm not sure what else to try. Jandy Pool Heater Won't Ignite [9 Easy Fixes] 1. It will run up from 65-80's with no problem then throws the error consistently at that point. Bad Pressure Switch 4. WISH I COULD FIND A COMPETENT SERVICE CO. THAT KNOWS WHAT THEY ARE DOING SO I COULD WORK ON CARS INSTEAD OF MY POOL HEATER. I'm not sure if it is a second chamber or if it is an inlet port from the bottom of the heater, for air to come in. We are a registered 501(c)3 non-profit that is funded by user donations. Apparently the bracket that holds it rusted and broke in half. Whenever he finds the perfect solutions to any issues of heating appliances after doing in-depth research, he loves to share them with his readers. After doing so, the heater started up just fine for about a week. Did you cycle the breaker after recommended? Hello , This is an inactive thread. Open the front panel, remove the internal cover #69, and then remove the single screw affixing the flame sensor rod and detach the electrical connector. Do you have a variablespeed, or two speed pump on this system? Cloudflare Ray ID: 7c0d33835de9a483 It seems to be the gas valve. Vocational, Technical or Tra. I took off the top grate and checked for debris. Pool and equipment are about six years old. Hopefully, now you have the answer to your question, Why is my Jandy pool heater not working?. 39. I removed the front panel and I see the wiring and boards in there. ivereplaced the presssure switch, blower pressure switch, ignition control unit, gas valve and flame sensor. A typical reading will be between 145 and 195 millivolts. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. I decided to get out and turned it off. The gas may flow initially but, then the gas valve may stop the flow because the pressure is too high/too low. Just because you smell gas, doesn't mean you are getting adequate flow. Section 11. I have a Jandy JXI400 heater. Your previous content has been restored. It's not super expensive but we see a lot replaced that are good. Fan starts running and cool air starts blowing from the top of the unit, and continues to blow until it shuts down2. Your heater will not ignite correctly if there is air in your gas line. Bad Flame Sensor 3. Please consider. But I have gas to the valve, I have checked voltage and resistance everywhere, and its all in range. Anyway after I put it back in after checking it, I did tighten the nuts carefully (not so tight as to crack the ignitor base) and still the until did not fire. That's weird. However, tonight, it had one. . I have a jandy LXI 400p. However, now the heater consistently cuts out around 82-85 degrees with a CHECK IGN STEPS error. Ran fine the first night. No failures in a little over 1 year so far. Examine the flue discharge for blockages or restrictions. Clear editor. I literally completely disassembled and reassembled the heater to figure out the fix. It could also be a tiny bit of condensation against the diaphragm. I read through the manual and found the whole ignition process (something like pre-blower, check air pressure sensor to let blower keep going, 15 second purge, then igniter gets warmed up, then gas, lastly flame sensor lets it stay on or kills the gas). The airflow switch is a safety device that trips when the heater isnt getting enough airflow. https://www.doheny.com/media/Pdfs/7609-instructions.pdf, JXi Heater - how do I check to see if the air flow sensor is working right, Pool heater is working but not heating water. Fluctuating filter pump pressure can cause the pump to burn out, lower water flow, and filter pressure problems. Reset The Jandy Pool Heater How Ro Reset The Jandy Pool Heater 5. I assume they were living in there this past winter. All Right Reserved by HeaterFixLab. Lets ask @Pool Clownand @jimmythegreek. I'd like to at least confirm that before risking my life with the 120vAC.. Shortly after opening the pool, I had to replace a cracked igniter. I tried to fire it up last weekend and it Ask an Expert Home Improvement Questions Pool And Spa Repair Question Summary Answer Summary Gaztech1 here, just signed in, 9H00 am eastern time in CANADA.good morning..I am ready to assist you with your issue. If not, the blower motor may be at fault. We called the gas company, they installed a larger meter (for free), and the problem never recurred. Little over 4 years old. Your link has been automatically embedded. If you run out of time before the controls time out shut down and repeat until all the wires are checked. The gas valve regulates the flow of gas into the manifold. In order to see it properly you need to release that panel and swing it out if you have not done this yet. PB is coming out again to check. I am having the same issue, but if I remove the yellow wire from the pressure sensor the fault light on the igniter comes on any ideas? pedanticus This usually indicates a problem in the line. You need to figure out which of these possible things are wrong with the blower. Firstly, check that the gas supply installed matches the gas type of the Jandy heater. Check the gas supply to make sure it matches the gas specified on the heaters rating plate. $20 OFF Chlorine Flash Sale. You will get much more visibility by. I have a voltmeter but no clue where to begin testing. Now this happens now and then since I bought the unit. Still havent had a plumber come. If you have an account, sign in now to post with your account. Fan Not Operating Or Running Slow 6. Trying to look up ways to troubleshoot, Im out of warranty, but Im comfortable working with panel. I decided to get out and turned it off. This means I'm scared of it. You will have to replace it. If you have an account, sign in now to post with your account. I have a Jandy JXI400 heater. In my case it was the sensor connections on the sensor mounted close to the blower motor that has a soft rubber hose connecting tube. Connect it to the pool pumps front to send the debris out to the skimmer box. I still am not getting any blinking at the LED on the panel. You can verify what the gas valve relay sounds like by closing the gas valve and jumping 24 vac to the gas valve connectors. From Google, I was able to figure out that this is indeed an Air Pressure switch (made by Honeywell): http://www.northamericahvac.com/servlet/the-5245/Honeywell-Air-Pressure-Switch/Detail. Installed winter of 2015. Disconnect power at the breaker. Im assuming you don't turn off power or disconnect the bonding? Then, connect the probes to the tips of the igniter plug. With over 200,000 members, TFP is the largest and most influential pool & spa website on the Internet. Never had a new heater with clogged jets, but i guess anything is possible while the heater is waiting in distribution. One last question, have you had a lightning strike or one close by lately? Is there a way to force the valve open? For a better experience, please enable JavaScript in your browser before proceeding. Otherwise you wouldn't be here. What do I do. read more. Worked until yesterday. You will get much more visibility by. A tripped breaker or fuse is one of the most typical causes. or Propane?). Could it be the gas pressure valve? Gave it maybe 5-10 minutes. Next stupid question: How do I see the ignitor? Do you smell any gas coming out of the exhaust? The code that appears on the display says Check IGN Steps and then shuts down. Pool installation company says "gas meter too small" but I have my doubts as there are 3 X 100,000 BTU/Hr furnaces in the house plus a 6 burner gas range and they have all been "on" in winter months. What was the final outcome. It is being practiced by thousands of pool owners just like you. Why does my pool heater say HP? Your previous content has been restored. my 16 year old lt just started displaying the AGS error. Natural gas is bone dry. If it works then that connection is bad. A gas regulator failure for a 4 year old heater is extremely rare.. Do you have access to a gas manometer? The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Same error. If it won't turn, the bearings are seized.and the motor will need to be replaced and is something you can do yourself. This test must be carried out with the power turned on. Set the multimeter to the Ohms setting. The sign next to it says it is an Ignition fault. There can be several reasons why your Jandy pool heater wont ignite. Once done trying to turn on the heat threw FAULT-CHECK IGN CONTROL. With that in mind, if anyone has any ideas, I'd be grateful. Clogged Pool Filter 2. I hear a click after about a minute, two minutes, and three minutes. 16. Jandy Pro Series JXi Pool Heater Troubleshooting Guide. Pool and equipment are about six years old. It may not display this or other websites correctly. Look at the glass eyeball to see if you see the igniter glowing. I ALSO HAVE A LXI 400 2 YEARS OLD, WORKED ONE DAY WHEN FIRST HOOKED UP, SERVICE TECHS SAID METER TOO SMALL, GAS CO. My Jandy JXI 400 heater is giving me a fault check ignite steps. That includes making sure you were sold the right heater (Gas? Original installer (2 years old) won't return calls and no one else will touch his work. When electrical power is added to the hot surface igniter, it transforms into a crystalline element that gets extremely hot. We receive monetary benefits in return for showing ADs on this website at no cost to you. UNIT PRE- PURGES 15 SEC, INGNITOR GLOWS 40 SEC, GAS VALVE OPENS, BURNER LIGHTS FOR 4 OR 5 SECONDS THEN IGNITION CONTROL CUTS POWER- NOT SENSING FLAME. I know you've reported it doesn't light at all but please check again. You can start by cleaning your pool filter. I was depending on the main regulator at the meter. If you have an account, sign in now to post with your account. That is because you need adequate airflow for ignition. On there is another Y/BK wire which goes to the air flow switch. Faulty Flame Sensor 3. You will get much more visibility by. The only thing I'd do before you verify the warranty is reset it by turning breaker off then on again. Hello , This is an inactive thread. Turned it back on. When the gas valve opens, you can smell the methyl mercaptan so I know there is gas getting in to the combustion chamber. Trees or other objects that would restrict unobstructed air passage to and from the vent terminal should be far away from the vent aperture. If voltage appears and the fan doesn't start, it's the motor. Then it worked for 2 months and now will not fire up. We had a Jandy lxi installed mid-winter in our home in Northern California. When I look at the troubleshooting section it says to ensure nothing is beneath the heater. It may not display this or other websites correctly. Gave it maybe 5-10 minutes. I noticed a 2nd host from the Honeywell air pressure sensor switch that goes to some other box down below behind the fire box. Only after detection does the gas valve open to light up the burners. Make sure you match the model#, the voltages, and the time durations! Hello , This is an inactive thread. I am having the exact same problem ipvfletch. Let's take it step by step STEP 1: TRANSFORMER CHECK If your heater has no power at all, check the circuit breaker or look for a popped GFCI outlet. What does ENA mean in a Jandy pool heater? I am having the same problem. Pool and equipment are about six years old. Also, there should be a debris trap close to the heater. There's a round hole that you can put a pencil in the hole to release the latch then swing it out to latch it out about 90 degrees. There are many ignition modules used in several industries that range from pools to HVAC to industrial dryers.they all look the same! It may not display this or other websites correctly. The only thing I have not done after reading some posts here, is to inspect the flame sensor wiring. I hear a click after about a minute, two minutes, and three minutes3. Little over 4 years old. Heater comes on, flash plate heats up, gas comes on read more. Just wanted to pass on about this piece of crap. What causes a pool heat exchanger to fail? We had this issue with our Jandy heater. I know you've reported it doesn't light at all but please check again. If the multimeter reads infinity or zero, the ignitor is broken and needs to be replaced. If there are no terminals visible, you may need to remove the cover first. Could be a connection issue. Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools. I can't even find the window. I'm guessing air must be pumped into the fire box or else the fire could not breathe, right? I believe the click you are hearing is the gas valve relay. The start sequence almost completes going through spinning up the fan and heating up the ignighter then there's this loud buzz and it stops the cycle. View online or download Jandy JXi 400 Installation And Operation Manual. Clear editor. Flawless operation, never had an issue ever. I think this is the Honeywell 1.0" WC PF thing I found in there. You must log in or register to reply here. It says Remote TSTAT enabled, which I believe is for my Jandy remote. I read through the manual and found the whole ignition process (something like pre-blower, check air pressure sensor to let blower keep going, 15 second purge, then igniter gets warmed up, then gas, lastly flame sensor lets it stay on or kills the gas). Any new postings here are unlikely to be seen or responded to by other members. ENA indicates that the heater is turned on but not running because it is not required. For a better experience, please enable JavaScript in your browser before proceeding. All you need to do is remove, clean, and replace. Sometimes we've had water accumulate in the line. Install Piping and Check Gas Supply. 38. To connect the hose to the bib, turn it clockwise. . I backwashed and that seemed to go away. Posted: October 25, 2017. Remove the wires from the terminals of the gas valve. It is a small rectangular flange with a nipple in the center for the hose. For Natural Gas: Minimum 4.0 W.C. to Maximum 10.5 W.C. For Propane: Minimum 4.0 W.C. to Maximum 14 W.C. Another pool season another heater issue Mastertemp 400 wont start, no error codes, JXi Heater - how do I check to see if the air flow sensor is working right, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. To clean blocked suction pipes, take a high-pressure attachment or drain king. The pool heater is giving me a fault ign check steps, Jandy pro series jxi400p, Yes we called pool company closed for Ask an Expert Home Improvement Questions Pool And Spa Repair The pool heater is giving me a fault ign check steps, Jandy Gaztech1, HVAC Technician Pool and Spa 2,717 Experience: HVAC technician Verified Manual cycles through this 3 times them displays the ags error. Our Jandy pro series jxi heater says check flow valve and Our Jandy pro series jxi heater says check flow valve and isnt heating.it was installed 1 month ago read more Poolservice123 Owner Associate Degree 1,028 satisfied customers When I turn pool heater on in shows int he display Fuselink I could have too much debris there, I don't know.. I still think you should rule out gas supply issues before you go any further. I also noticed right now the heater says "no flow" because my pump was off. Removed the cover and set it aside with power disconnected at the breaker. For a better experience, please enable JavaScript in your browser before proceeding. You can email the site owner to let them know you were blocked. Here is what I know so far: - water switch operates correctly (closes when there is water flow, open when no flow - yes, I have an ohm meter and know how to use it..), - Gas line pressure 7.5 inches water column into the heater and at inlet to gas valve, - Manifold pressure 2.5 inches when gas valve opens and heater attempts to light (this is the required pressure according to the sticker on the air plenum cover), - induces draft fan (blower works fine, pressure in the burner throat is the required 1.0 inches of water column), - ignitor glows red hot when control calls for it to attempt to light. Brand: Zodiac Pool Systems REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. New valve should be here in a few days, hopefully at same time as plumber. Gas leaks can be very dangerous and lethal. Next time it fails, without doing anything else, check for voltage across the air switch terminals and the water pressure switch terminals. Any thoughts or suggestions appreciated as I wait for the gas company to install a new meter in about 3 weeks.. which I do not really expect to solve the problem. It is Propane I know that much. Please check all the valves from the heater back to your meter. You should read zero volts across the terminals. I can't speak for is this is a common issue or not as I haven't seen or heard of such.

Patti Lease Souza Obituary, Clearwater, Florida Obituaries 2021, Articles J